Certificate of Analysis

* For quality assurance purposes. Not a Maine compliance certificate.

Square One - Hemp Gummies - Sample 3 (Edible Solid)

Produced: Jul 30, 2021

Client: Square One, LLC // Batch Result: Passed

Img

Batch No.: 07182021

Matrix: Edible Solid

Sample ID: NAL-210722-073

Collected On: Jul 22, 2021

Received On: Jul 22, 2021

Sample Size: 20 Units

Received By: Andrew Patterson

Serving Size: 4.0838 g

CBD

10.5 mg/srv

10.5 mg/srv

CBCA

0.00 mg/srv

0.00 mg/srv

Total Cannabinoids

10.5 mg/srv

10.5 mg/srv

Cultivator

Bobbie Stormann

License

CGR29760

Type

Medicinal - Caregiver

Results Certified By:

Barry Chaffin

COO, Nova Analytic Labs

Jul 30, 2021

Signature

Results Certified By:

Greg Newland

CSO, Nova Analytic Labs

Jul 30, 2021

Signature

Results Certified By:

Chris Altomare

CEO, Nova Analytic Labs

Jul 30, 2021

Signature

Nova Analytic Labs // 65 Milliken Street, Unit C Portland ME 04103 // PH: 2074664661

Email: innovation@nova-analyticlabs.com

ME License #: TF284

https://lims.tagleaf.com/coa_/kl4utqCqzX

CAN.1: Potency & Cannabinoid Profile by HPLC-UV

Preparation: Jul 23, 2021

Analysis: Jul 26, 2021

Reported on an as received basis
1000 µg/g = 1 mg/g

Analyte Detected Pass/Fail
CBC < LOQ N/A
CBCA ND N/A
CBD 0.256 % N/A
CBDA ND N/A
CBDV < LOQ N/A
CBDVA ND N/A
CBG < LOQ N/A
CBGA ND N/A
CBL ND N/A
CBLA ND N/A
CBN ND N/A
CBNA ND N/A
Δ8-THC ND N/A
Δ9-THC < LOQ N/A
Δ10-THC ND N/A
Exo-THC ND N/A
THCA ND N/A
THCV ND N/A
THCVA ND N/A
Total THC
(Total THC = (THCA x 0.877) + THC)
< LOQ N/A
Total CBD
(Total CBD = (CBDA x 0.877) + CBD)
0.256 % N/A
CBD Per Serving
Serving: 4.0838 Grams
10.5 Milligrams N/A
Δ9-THC Per Serving
Serving: 4.0838 Grams
< LOQ N/A
Total THC Per Serving
Serving: 4.0838 Grams
< LOQ N/A
Total CBD Per Serving
Serving: 4.0838 Grams
10.5 Milligrams N/A

MIC.6: Total Enterobacter by Most Probable Number

Preparation: Jul 27, 2021

Analysis: Jul 28, 2021

Analyte Detected Pass/Fail
Enterobacteriaceae ND N/A

MIC.3: Total Coliform by Most Probable Number

Preparation: Jul 27, 2021

Analysis: Jul 28, 2021

Analyte Detected Pass/Fail
Coliforms ND N/A

Total Aerobic Bacteria by Most Probable Number

Preparation: Jul 27, 2021

Analysis: Jul 28, 2021

Analyte Detected Pass/Fail
Aerobic Bacteria ND N/A

MIC.4: Pathogenic E. coli by PCR

Preparation: Jul 27, 2021

Analysis: Jul 29, 2021

Analyte Detected Pass/Fail
Escherichia coli ND N/A

MIC.5: Salmonella by PCR

Preparation: Jul 27, 2021

Analysis: Jul 29, 2021

Analyte Detected Pass/Fail
Salmonella spp. ND N/A

Total Yeast and Mold by Most Probable Number

Preparation: Jul 27, 2021

Analysis: Jul 30, 2021

Analyte Detected Pass/Fail
Yeast & Mold ND N/A

MYC.1: Mycotoxins by LC-HRMS

Preparation: Jul 27, 2021

Analysis: Jul 27, 2021

Analyte Detected Pass/Fail
Aflatoxin B1 ND N/A
Aflatoxin B2 ND N/A
Aflatoxin G1 ND N/A
Aflatoxin G2 ND N/A
Ochratoxin A ND N/A

PES.1: Pesticides, Insecticides, Fungicides and Growth Regulators by LC-MS/MS

Preparation: Jul 27, 2021

Analysis: Jul 27, 2021

Analyte Detected Pass/Fail
Imazalil ND N/A
Etoxazole ND N/A
Bifenthrin ND N/A
Cyfluthrin ND N/A
Analyte Detected Pass/Fail
Daminozide ND N/A
Myclobutanil ND N/A
Spiromesifen ND N/A
Trifloxystrob-
in
ND N/A

HME.1: Heavy Metals by ICP-MS

Preparation: Jul 27, 2021

Analysis: Jul 27, 2021

Analyte Detected Pass/Fail
Lead ND N/A
Arsenic ND N/A
Cadmium ND N/A
Mercury ND N/A

* For quality assurance purposes. Not a Maine compliance certificate.

ALL TESTS WERE PERFORMED IN ACCORDANCE WITH THE RULES AND REGULATIONS SET FORTH IN THE MAINE ADULT USE PROGRAM. LABORATORY SAMPLING PROTOCOLS ARE GOVERNED BY THE OCP'S SAMPLING GUIDANCE DOCUMENTS. ALL INFORMATION PROVIDED BY THE CLIENT, INCLUDING SELF SAMPLING, MUST BE ACCURATE AND ADHERE TO THE SAME RULES AND REGULATIONS. HOWEVER, CLIENT PROVIDED INFORMATION, INCLUDING SAMPLING, IS ULTIMATELY THE RESPONSIBILITY OF THE PROVIDING LICENSEE, REGISTERED CAREGIVER, PATIENT OR THE LIKE AND FAILURE TO FOLLOW SAID PROTOCOLS COULD LEAD TO ERRONEOUS TEST RESULTS. NOTE: NOT ALL POTENTIAL AND/OR EXISTING HAZARDS WERE ANALYZED. THIS CERTIFICATE OF ANALYSIS IS RELEVANT ONLY TO THOSE ITEMS TESTED. THE SAMPLE WAS PROVIDED TO THE LABORATORY FOR TESTING BY THE CLIENT AND THE SAMPLE WAS TESTED AS RECEIVED.

End of Report